Skip to content

230V Dimmmers


  • Zennio DIMinBOX DX4 4 channels universal KNX dimmer actuator ZDIDBDX4

    Zennio DIMinBOX DX4 4 channels universal KNX dimmer actuator ZDIDBDX4

    Main features :

    • Universal dimming actuator (RLC, LED, CFL) for DIN rail (8u) with 4 channels 300 W @ 230 VAC (200 W @ 110 VAC)
    • Allows joint control of channels: dual channel up to 600 W at 230 VAC (400 W @ 110 VAC), quad channel up to 1200 W at 230 VAC (800 W @ 110 VAC).
    • Automatic load detection (RLC)
    • Configurable LED and CFL dimming curves
    • Allows manual control by means of push buttons
    • Has 10 independent logic functions
    • Detection of short-circuit, power failure, overvoltage, overheating, abnormal frequency and incorrect settings.


    Safety instructions :

    • The equipment must only be installed by qualified electricians and in accordance with the accident prevention regulations. Do not connect the main voltage (110-230VAC) or other external voltages to the KNX Data Bus. Connecting an external voltage may endanger the electrical safety of the entire KNX system.
    • Once installed, the device must not be accessible from the outside.
    • In case of load change, disconnect the main voltage (110-230VAC).
    • Always check during installation that there is sufficient insulation between the conductors of the 110-230VAC main voltage and the conductors of the KNX Bus and its extensions.
    • Do not expose the device to rain or moisture, nor block the ventilation openings.
    • Failure to follow the installation instructions may cause fire and other damage.

    320.00 €
  • Zennio NarrowDIM X4. universal dimmer. 4 channels. ZDINDX4

    Zennio NarrowDIM X4.  universal dimmer. 4 channels. ZDINDX4

     

    Universal dimming actuator (RLC, LED, CFL*) for DIN-rail (4.5 units) with 4 channels for up to 210 W at 230 VAC (160 W at 110 VAC). It allows double channel connection, up to 400 W at 230 VAC (300 W at 110 VAC) and quad channel connection to control up to 750 W at 230 VAC (600 W at 110 VAC). Auto load type detection (RLC). Configurable dimming curves for LED and CFL. It allows manual control of its outputs through the push buttons on the cover. It includes 10 independent logical functions. Error detection: short circuit, voltage surge, overheating, anomalous frequency, power failure, parameterization error. *Only dimmable loads.

    288.00 €
  • JUNG KNX light-dimmer 4 outputs 390041SR

    JUNG light-dimmer 4 outputs KNX Modulaire 4 X 200 W OU 4 X 35 W EN LED TYPE GU10 390041SR

    4 x 225 W, HV LED lamps typ. 4 x 1 ... 35 W (leading edge phase control), 4 x 1 ... 200 W (trailing edge phase control)
    1 x 855 W
    rail mounting device, 4 rail units
    with manual electronic operation and LED status indication
    Project design and commissioning with ETS5 or a more recent version
    ETS product family: Illumination
    Product type: Dimmer

    302.00 €
  • Zennio DIMinBOX DX2 KNX 2 channels universal dimmer actuator ZDI-DBDX2

    Zennio DIMinBOX DX2  KNX 2 channels universal dimmer actuator ZDI-DBDX2

    Main characteristics:

    • 2 channels of 310W each or 1 channel of 600W at 230VAC, (2 channels 200W or 1 channel 400W at 125VAC)
    • 2 channels for R L C type loads and/or variable LED bulbs and low consumption.
    • Automatic detection of the R L C load type.
    • Choice of dimming curves for LEDs and low consumption.
    • Manual control of the dimming possible.
    • 2 analog/digital inputs.
    • Designed to be placed in any electrical box with DIN rail.
    • Integrated KNX BUS coupling unit.
    • Data backup in case of power loss.
    • Complies with EC directives


    Safety instructions :

    • The equipment must only be installed by qualified electricians and in accordance with the accident prevention regulations. Do not connect the main voltage (110-230VAC) or other external voltages to the KNX Data Bus. Connecting an external voltage may endanger the electrical safety of the entire KNX system.
    • Once installed, the device must not be accessible from the outside.
    • In case of load change, disconnect the main voltage (110-230VAC).
    • Always check during installation that there is sufficient insulation between the conductors of the 110-230VAC main voltage and the conductors of the KNX Bus and its extensions.
    • Do not expose the device to rain or moisture, nor block the ventilation openings.
    • Failure to follow the installation instructions may cause fire and other damage.

    199.00 €
  • Zennio NarrowDIM X2. universal dimmer. 2 channels. ZDINDX2

    Zennio NarrowDIM X2. universal dimmer. 2 channels. ZDINDX2

     

    FEATURES
    • 2 channels for R L C loads and for dimmable CFL and LED lamps
    • Automatic detection of R L C load type
    • Automatic frequency detection
    • Dimming pattern selection for CFL and LED lamps
    • Optional manual dimming control
    • Total data saving on KNX bus failure
    • Integrated KNX BCU (TP1-256)
    • Dimensions 67 x 90 x 36 mm (2 DIN units)
    • DIN rail mounting according to IEC 60715 TH35, with fixing clamp
    • Conformity with the CE, UKCA, RCM directives (marks on the right side)*Only dimmable loads.

    181.00 €
  • Schneider KNX - Universal Dimmer Master 2 channel- MTN6710-0102

    Schneider KNX - Universal Dimmer Master 2 channel- MTN6710-0102

    Can be installed in combination with the dimmer extension  (to obtain dimmable 4 or 6 outputs ):

    Schneider KNX - Universal Dimmer 2 channel - extension - MTN6810-0102

    Can be installed in combination with the extension switch-blind actuator (to obtain dimmable 2 outputs and  8 or 16 switch-blind outputs):

    Schneider KNX - Switch-blinds actuator 8 outputs - extension - MTN6805-0008

    Can be installed in combination with the extension switch-blind actuator and Universal Dimmer 2 channel - extension(to obtain dimmable 4 outputs and  8  switch-blind outputs):

     

     

     If your extension is not side by side with the master or the second extension you can use this cable:

    Schneider KNX Cable flexible

     

    SpaceLogic KNX Universal Dimming Master. Dimming actuator with 2 channels for switching and dimming dimmable LED lamps, incan -descent lamps, HV halogen lamps, LV halogen lamps using dimmable wound transformers or electronic transformers or dimmable compact fluorescent lamps. (leading and trailing-edge phases)

     

    181.20 €
  • Schneider KNX - Universal Dimmer extension 2 channel- MTN6810-0102

    Schneider KNX - Universal Dimmer estension 2 channel- MTN6810-0102

    Must be installed in combination with the dimmer master  (to obtain 4 or 6 outputs):

    Schneider KNX - Universal Dimmer 2 channel - master - MTN6710-0102

     If your extension is not side by side with the master or the second extension you can use this cable:

    Schneider KNX Cable flexible

     

    The SpaceLogic KNX Universal Dimming Extension is a dimming actuator that extends the channels of a SpaceLogic KNX Universal Dimming Master. For independent control of up to 2 dimmable loads such as dimmable LED lamps, incan -descent lamps, HV halogen lamps, LV halogen lamps using dimmable wound transformers or electronic transformers or dimmable compact fluorescent lamps. (leading and trailing-edge phases)

     

    129.00 €
  • JUNG 2 channels KNX dimmer actuator 2x300W 3902REGHE

    KNX universal LED dimmer actuator, 2 outputs

     2 x 300W outputs for incandescent lamps 230 V or 4 x 7 to 50 W outputs for 230 V LED lamps 
    ETS product family: Lighting
    Type: Dimmer

    Intended use

    Switching and variation:

    • incandescent lamps
    • HV halogen lamps
    • Tronic transformers with halogen lamps
    • variable inductive transformers with halogen or LED lamps
    • HT LED lamps
    • compact fluorescent lamps
    • Mounting on DIN rail in a sub-distributor according to EN 60715

    Product features

    • Automatic or manual selection of the variation principle adapted to the load
    • Secure against no-load operation, short circuits and overheating
    • Short circuit message
    • Manually controllable outputs
    • Return of the switching state and the change value
    • Parameterizable variation and activation
    • Timer functions: switch-on delay, switch-off delay, staircase light switch and warning function Light scene operation
    • Locking of individual outputs manually or by bus
    • LED status display of the outputs
    • Operating hours counter
    • A power failure longer than approx. 5 seconds will deactivate the dimming actuator. Depending on the parameter setting, the connected load is measured again after the mains voltage is restored.

    237.60 €